Hybrid Inverter

Basic Specification:

 Solar Array Size (Solar input)
3kW, 4kW, 5kW, 6.5kW
Sizes available (power output)
3kW, 3.68kW, 4.6kW, 6kW (3kW in backup mode)
Battery System Voltage
48V


Use modes:

Self-use(with PV power)
Self-use(with PV power)
Force time use
Force time use
back up mode
off-grid
Priority: Load>battery>grid
Battery discharge for load
Priority: Battery>load>grid(When charging)
Priority: Load>battery>grid(When discharging)
Priority: Battery>load>grid
Generated solar energy
Generated solar energy
Grid supply power when the battery capacity is not enough
Generated solar energy
Generated solar energy
Generated solar energy
Self-use from battery
Load consumption
Load consumption
Storage in Battery
Load consumption
Storage in Battery
Load consumption
Storage in Battery

Load consumption
Self-use from battery
Load consumption

Feed the remaining solar energy into the grid

Grid supply power when the battery capacity is not enough
Grid supply power when the battery
Grid supply power

image.png
image.png
image.png
image.png
image.png
image.png


Product Feature


Product Application

image.png

image.png

image.png

Product Specification

Spec. MKSE-ESC3000  MKSE-ESC4000  MKSE-ESC5000 
PV Input Data
Max. PV-Generator Power 3300W 4000W 5000W
Max. DC Voltage 580V
MPPT Voltage Range 110~550V
Start-up Voltage   110V
Min. DC Voltage 75V
Max. DC Current 12A/12A
Numbers of MPPT 2
Strings per MPPT 1
Type of DC Connector MC4
AC Output Data (On-grid)
Norminal AC Power 3000W 3680W 4600W
Max. AC Power 3000W 3680W 4600W
Max. AC Current 13A 16A 21.7A
Nominal AC Voltage/ Range 230V/180-270V
Grid Frequency/ Range 50Hz/60Hz 45~55Hz/55~65Hz
Output Power Factor 0.8leading~0.8lagging (full load)
Output THDi (Nominal Output) <3%
AC Output Data (Back-up)
Max. Output Apparent Power  3000W
Nominal Output Voltage 230V
Nominal Output Frequency 50/60Hz
Max. Output Current 10A
Harmonic Distortion (THD) at Rated Output <3%
Automatic Switch Time <5s
Peak Power (W), Duration 3500W, 10s
Battery Input Data
Battery Type Lead-acid battery/ Lithium battery
Norminal Battery Voltage 48V
Battery Voltage Range 40~60V
Max. Charging/ Discharging Current 60A
Communication Interfaces Can
Efficiency
Max. Efficiency 97.60% 97.60% 97.60%
Euro efficiency 97.00% 97.00% 97.00%
MPPT Adaptation Efficiency 99.90% 99.90% 99.90%
General Data
Dimension (W*H*D) 526*528*178mm
Weight 29.5kg
Mounting Wall Mounted
User Interface LCD
Communication Ethernet(Standard),RS485(Optional),Wifi(Optional)
Operating Temp. Range -25~60℃ (>45℃ Derating operation)
Relative Humidity 0-98% (No condensation)
Operating Altitude 4000m (>2000m Derating operation)
Standby Self Consumption <1W
Topology Transformerless
Cooling Transformerless
Protection Grades IP65
Noise <35db
Warranty year(Standard), 10/15/20/25 year(Optional)
Certifications IEC 62109-1, IEC 62109-2, AS/NZS 3100, VDE-AR-N-4105, VDE 0126-1-1+A1, CE, G59/3, UTE C15-712-1, 
MEA, PEA, AS4777, EN50438, NB/T32004-2013, CEI-021, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, 
EN 61000-6-4, EN 61000-4-16, EN 61000-4-18, EN 61000-4-29